Highlights
Task:
Overview of Assignment
Your proposed granny flat project (CDC) is to be constructed using timber framing in a non-cyclonic wind classification zone – category N2. You are required to design the timber framing members in accordance with the AS1684 Residential Timber-Framed Construction and the HySPAN tables where required. The HySPAN tables have been uploaded to the Assignment 2 folder on vUWS. Note: You can download the free copy of the AS1684.4 2010 from the WSU Library website through: Standards On-Line Premium (SAI Global) by copying and pasting the below link. https://subjectguides.library.westernsydney.edu.au/buildingandconstruction
AS1684 has four parts; these include: Part 1 Design criteria; Part 2 Non-cyclonic areas; Part 3 Cyclonic areas; and Part 4 Simplified - non-cyclonic areas. This standard is the only framing standard adopted by the NCC/BCA as a deemed-to-satisfy solution for structural timber framework. However, there are other standards for structural steel framework and brickwork together with commercially based timber engineered solutions, such as the Hyspan tables we will also use.
Task
There are three sections for this assignment. Each section has some sub-questions. To answer these questions, you are required to utilise the appropriate AS1684 and Hyspan tables, floor plans and elevations, located on vUWS under Assignment 2.
SECTION 1 - Wall and roof framing (17.5 marks)
· Using the tables from AS1684, calculate the minimum size (spans, lengths, heights and sectional size etc) of the nominated timber members which will act as a uniform construction for the Elevations wall frames of your project home. NB: Drawings indicate a sheet (metal), trussed roof @ 4.5 deg. pitch. Assume wall studs at 450mm centres with 90/100mm frame. Use only SEASONED timber as nominated and DO NOT use alternative sections as noted in Table A1.
Q1. (3 Mark) F8
Q2. (1 Mark) F8
Common wall studs
(not notched)
Use the stud height’
XX x XX mm Bottom Plates (not trenched) XX x XX mm
Q3. (1 Mark) MGP10 Q4. (2 Mark) F8
Top Plates
(not trenched)
XX x X
The above Management Assignment has been solved by our Management Assignment Experts at onlineassignmentbank. Our Assignment Writing Experts are efficient to provide a fresh solution to this question. We are serving more than 10000+ Students in Australia, UK & US by helping them to score HD in their academics. Our experts are well trained to follow all marking rubrics & referencing style.
Be it a used or new solution, the quality of the work submitted by our assignment experts remains unhampered. You may continue to expect the same or even better quality with the used and new assignment solution files respectively. There’s one thing to be noticed that you could choose one between the two and acquire an HD either way. You could choose a new assignment solution file to get yourself an exclusive, plagiarism (with free Turnitin file), expert quality assignment or order an old solution file that was considered worthy of the highest distinction.
© Copyright 2026 My Uni Papers – Student Hustle Made Hassle Free. All rights reserved.