Common - Emitter Current - Gaussian Profile - Velocities - Engineering Assignment Help

Download Solution Order New Solution
Assignment Task :

We want to simulate an np-n BJT with PC1D
1. Use an n-type Si wafer with an area of 1 mm2, 
2. a thickness of 5 μm, 
3. a background doping of 1×1015 cm-3. 
Commonly the base and emitter are formed by diffusion processes. 
1. The base diffusion has a Gaussian profile with a depth factor of 0.2 μm and a peak doping of 1×1018 cm-3 (1st front diffusion). 
2. The emitter diffusion has an erfc profile with a depth factor of 0.1 μm and a peak doping of 1×1020 cm-3 (2nd front diffusion). 
3. Further, assume a lifetime of 0.05 μs and surface recombination velocities of 1000 cm/s. 
4. Enable all contacts and set the emitter and base internal series resistances to 1×10-6 Ω and the collector series resistance to 0.1 Ω. 
5. The base contact should be at 0.35 μm from the front surface. 

 

Excitation/Simulation: 
1. The excitation should be transient with 86 time steps and a time step size of 0.5 s. 
2. Set the first time step at t = 0 to 1×10-9. 
3. For the base circuit load the external file (located in the PC1D main folder) ib.vlt and for the collector circuit vce.vlb. 
This will create a family of common-emitter curves. The curves for collector current correspond to 0.1, 0.2, 0.3 and 0.4 mA of base current, while the collector-emitter voltage is scanned in a range between 0 and 5 Volts. 
 

Deliverables: 
1. Simulate the collector current vs. collector-emitter voltage characteristics. 
2. Determine the common-emitter current gain β.  
3. Determine the emitter efficiency, assuming the base transport factor is unity (1.0).
4. What happens to β if the base diffusion is too deep (depth factor of 0.5 μm). Explain the behavior. 
5. What happens to β if the emitter doping is too low (peak doping of 5×1018 cm-3). Explain the behavior. 

 

This Engineering Assignment has been solved by our Engineering Experts at My Uni Paper. Our Assignment Writing Experts are efficient to provide a fresh solution to this question. We are serving more than 10000+ Students in Australia, UK & US by helping them to score HD in their academics. Our experts are well trained to follow all marking rubrics & referencing style.

Be it a used or new solution, the quality of the work submitted by our assignment experts remains unhampered. You may continue to expect the same or even better quality with the used and new assignment solution files respectively. There’s one thing to be noticed that you could choose one between the two and acquire an HD either way. You could choose a new assignment solution file to get yourself an exclusive, plagiarism (with free Turnitin file), expert quality assignment or order an old solution file that was considered worthy of the highest distinction.

Get It Done! Today

Country
Applicable Time Zone is AEST [Sydney, NSW] (GMT+11)
+

Every Assignment. Every Solution. Instantly. Deadline Ahead? Grab Your Sample Now.