Assignment Task

 

1. 3-phase fault on Bus 1 and Bus 4.

o Information and Instruction

- S base = 100 MVA, V base = 110 kV.

- Prefault voltage = 1.05∠0° p.u at all buses

- The load (M: Motor) presents in the same manner as a synchronous machine at the fault moment.

- In your solution, present the current value in p.u and Amperes.

 

a) Draw the per-unit impedance diagram.

b) Calculate the Thevenin's equivalent impedance in p.u when the fault occurs at Bus 1.

c) Calculate the sub-transient fault current (????"????1)using Thevenin's method, and Calculate the fault current contribution through G (????"????1 ) and M (????"????1 ). [Bus 1 Fault]

d) When the load (M: Motor) is being operated at 100 MVA, power factor = 0.85 lagging, at 1.05pu voltage, calculate the load current (???????? ) and calculate the summation of the sub-transient current and the load current ???????? at G (????"????1 ) and M(????"????1 ). [Bus 1 Fault] (Make sure the direction of the fault current and load current.)

e) Calculate the Thevenin's equivalent impedance in p.u when the fault occurs at Bus 4.

f) Calculate the sub-transient fault current (????"????4)using Thevenin's method, and Calculate the fault current contribution through G (????"????1 ) and M (????"????4 ). [Bus 4 Fault]

g) calculate the summation of the sub-transient current and the load current ???????? at G (????"????4 ) and M(????"????4 ). [Bus 4 Fault] (Make sure the direction of the fault current and load current.)

h) Verify your calculation using Power World Simulation fault analysis.

- On Bus 4, put the Generator (because The load (M: Motor) presents in the same manner as a synchronous machine at the fault moment.)

- Put the sub-transient parameters for Generator and Motor reactance (“Internal Sequence Impedance– Positive”).

- Your fault analysis results only show the sub-transient current. The simulation runs without the load current. (with only two generators)

- The snapshots of the fault results must be attached as shown below.

: Attach the line diagram.

: Attach the snapshot of the fault analysis result of Bus 1 Fault and alalyse it.

: Attach the snapshot of the fault analysis result of Bus 4 Fault and analyse it.

  • The introduction of this report is NOT required.

 

This ELEN3001-Engineering Assignment has been solved by our Engineering Experts at My Uni Paper. Our Assignment Writing Experts are efficient to provide a fresh solution to this question. We are serving more than 10000+ Students in Australia, UK & US by helping them to score HD in their academics. Our Experts are well trained to follow all marking rubrics & referencing Style. Be it a used or new solution, the quality of the work submitted by our assignment experts remains unhampered.

You may continue to expect the same or even better quality with the used and new assignment solution files respectively. There’s one thing to be noticed that you could choose one between the two and acquire an HD either way. You could choose a new assignment solution file to get yourself an exclusive, plagiarism (with free Turn tin file), expert quality assignment or order an old solution file that was considered worthy of the highest distinction.

Get It Done! Today

Country
Applicable Time Zone is AEST [Sydney, NSW] (GMT+11)
+

Every Assignment. Every Solution. Instantly. Deadline Ahead? Grab Your Sample Now.