OLTC Control Systems - Topology - Engineering Assignment Help

Download Solution Order New Solution
Assignment Task:

Proposal

topology

Topology 3 corresponds to the conventional voltage regulators that are utilized in the grid. It consists of an autotransformer with taps on the series winding at the secondary side. A selector switch connects either the top or the bottom of the series winding LV side to the primary HV side so as to provide negative or positive compensation respectively.

topology 7

  • In an attempt to use a single transformer for compensation that is rated only for the compensating power of 0.1p.u., topology 7 is obtained. They use a step-down type center-tapped series transformer. The transformers have a turn ratio of 100:1 and 20:1 respectively. 
  • In topology 7, the taps are moved to the secondary side - the benefit being that the switch voltage ratings in OFF condition are reduced. The drawback of this design is that the tap switches directly carry the load current and are not isolated from the source or load. A selector switch determines the polarity of the compensation voltage. The series transformer primary and secondary is rated for 2p.u. and 0.1p.u voltage respectively. To evaluate the ratings of the switches - when one tap is ON, say S1 providing 10% compensation, the other switches will have to block up to 0.1p.u voltage. The selector switch has to block ±2 p.u.

NOTE::
ALL THE RESULT (GRAPH OR FIGURE) MUST HAVE EXPLANATION.  THE MAIN REASON OF THIS PROJECT IS TO COMPARE BOTH TOPOLOGY 3 AND 7. 
Objective

  • To develop OLTC control systems that can help maintain the grid voltage within the standard levels using the latest technologies.
  • To evaluate the performance of the proposed system in terms of energy-saving while the power quality is not violated.

 

This Engineering Assignment has been solved by our Experts at My Uni Paper. Our Assignment Writing Experts are efficient to provide a fresh solution to this question. We are serving more than 10000+ Students in Australia, UK & US by helping them to score HD in their academics. Our experts are well trained to follow all marking rubrics & referencing style.

Be it a used or new solution, the quality of the work submitted by our assignment experts remains unhampered. You may continue to expect the same or even better quality with the used and new assignment solution files respectively. There’s one thing to be noticed that you could choose one between the two and acquire an HD either way. You could choose a new assignment solution file to get yourself an exclusive, plagiarism (with free Turnitin file), expert quality assignment or order an old solution file that was considered worthy of the highest distinction.

 

Get It Done! Today

Country
Applicable Time Zone is AEST [Sydney, NSW] (GMT+11)
+

Every Assignment. Every Solution. Instantly. Deadline Ahead? Grab Your Sample Now.